New Flame Sensors

The change in flame sensor technology from the previous Photoresistor has been driven by EU legislation RoHS 2011/65/EU that must be complied with prior to July 2019. Riello has now implemented the introduction for the new compliant cells into all its affected oil burner models.
Particular attention is needed for RDB models. The old photocell was a very simple component that could be used with both analogue and digital burner control boxes, however the new cadmium free technology incorporates both a sensing cell + PCB contained within the flame sensor itself.
Different cells are now needed for RDB dependant on which control box is in use, Analogue or Digital and making the right spare part selection is important as if the wrong cell is chosen the burner will not work and may lead to wrong diagnosis that the new cell has failed.

Burner models affected are as follows:

 

CURRENT SPARES
CODE
CONTROL
BOX TYPE
BURNER SERIES
NEW SPARES
CODE
HOUSING
TYPE
NOTE
3002280
ANALOGUE
PRESS, RIELLO 40
20132573
STANDARD
DIRECT REPLACEMENT
3007839
ANALOGUE
GULLIVER
20132566
SHORT
DIRECT REPLACEMENT
3007541
ANALOGUE
RDB
20132553
SHORT
THE CORRECT REPLACMENT DEPENDS ON THE CONTROL BOX TYPE – ANALOGUE OR DIGITAL
DIGITAL
RDB
20132574
SHORT
3008646
ANALOGUE
RDB
20132526
STANDARD
DIGITAL
RDB
20132550
STANDARD

> Back to news

Get In Touch With Us...

Please contact us directly on +44 (0)1480 432144, or alternatively send your enquiry through using the form below.

I give consent for Riello Burners to contact me via the following methods for marketing purposes:

 
 

Copyright © Riello Limited 2019
Site by Verto

Signup to our Newsletter

Riello Burners UK

The Ermine Centre, Ermine Business Park, Huntingdon, Cambridgeshire. PE29 6WX

Contact Us

t: +44 (0) 1480 432144
f: +44 (0) 1480 432191
e: info@rielloburners.co.uk